Customization: | Available |
---|---|
DC Input: | Customized |
Input Rang: | Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Loading rate | It is recommended that the load rate of general types of loads under continuous operation should be controlled within 80%, and that of power motors such as inductive, capacitive, power amplifier and radio should be about 50%, because the dynamic power of these types of loads changes greatly. |
Working hours | Allow 24-hour uninterrupted work |
Overload overcurrent | 105-135% start with load |
Undervoltage protection | Start under - 18% of input voltage |
Overvoltage protection | Start with input voltage above + 18% |
No load power consumption | <3W |
No load current | 0.2A |
Overload protection | Overload 105% ~ 135% enters the protection range |
Start time | 1-2s (soft start) |
Earthquake resistance | 10 ~ 500Hz, 2G, 10 seconds / 1 cycle, 60 minutes in total, each axis |
Withstand voltage | Input / output room: 1.5kVac, input and housing: 1.5kVac, output and housing: 0.5kvac |
Isolation | Input and output isolation status; |
Isolation resistance | Input / output room, input and housing, output and housing: 500VDC / 100M ohms |
Operating temperature / humidity | -30ºC~+65ºC,20%~90%RH |
Storage temperature / humidity | -40ºC~+85ºC,10%~95%%RH |
Overall dimension | 238*124*65mm |
Shell material | Aluminum alloy |
Net weight of complete machine | 1.5KG |
Model | Input voltage | Output voltage | Max output current | Continuous current | Max power | Continuous power | Efficiency |
IPS-DTD12S12-83.3 | 12VDC±15% | 12V±1-2% | 83.3A | 66.6A | 1000W | 800W | 90±4% |
IPS-DTD12S24-41.6 | 12VDC±15% | 24V±1-2% | 41.6A | 33.3A | 1000W | 800W | 90±4% |
IPS-DTD12S36-27.7 | 12VDC±15% | 36V±1-2% | 27.7A | 22.2A | 1000W | 800W | 90±4% |
IPS-DTD12S48-20.8 | 12VDC±15% | 48V±1-2% | 20.8A | 16.6A | 1000W | 800W | 90±4% |
IPS-DTD12S64-15.62 | 12VDC±15% | 64V±1-2% | 15.62A | 12.5A | 1000W | 800W | 90±4% |
IPS-DTD12S100-10 | 12VDC±15% | 100V±1-2% | 10A | 8A | 1000W | 800W | 90±4% |
IPS-DTD12S150-6.6 | 12VDC±15% | 150V±1-2% | 6.6A | 5.3A | 1000W | 800W | 90±4% |
IPS-DTD12S200-5 | 12VDC±15% | 200V±1-2% | 5A | 4A | 1000W | 800W | 90±4% |
IPS-DTD12S220-4.5 | 12VDC±15% | 220V±1-2% | 4.5A | 3.6A | 1000W | 800W | 90±4% |
IPS-DTD12S250-4 | 12VDC±15% | 250V±1-2% | 4A | 3.2A | 1000W | 800W | 90±4% |
IPS-DTD12S280-3.57 | 12VDC±15% | 280V±1-2% | 3.57A | 2.8A | 1000W | 800W | 90±4% |
IPS-DTD12S300-3.33 | 12VDC±15% | 300V±1-2% | 3.33A | 2.6A | 1000W | 800W | 90±4% |
IPS-DTD12S350-2.85 | 12VDC±15% | 350V±1-2% | 2.85A | 2.28A | 1000W | 800W | 90±4% |
IPS-DTD12S400-2.5 | 12VDC±15% | 400V±1-2% | 2.5A | 2A | 1000W | 800W | 90±4% |