Customization: | Available |
---|---|
Nature of Source Flow: | / |
Certification: | RoHS, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | Home Appliances |
2 | Power Tools, |
3 | Office And Portable Equipment |
4 | Vehicles And Yachts |
5 | Etc |
1 | Pure sine wave output (THD<3%) |
2 | Instantaneous power up to 6000W |
3 | LCD display: Battery power % ratio, battery voltage, AC voltage, AC power, temperature display |
4 | Smart Fan Control |
5 | Support OEM/ODM |
1 | Battery Low Voltage Prompt |
2 | Battery Low Voltage Protection |
3 | Battery High Voltage Protection |
4 | Internal Over-Temperature Protection |
5 | Ac Overload Protection |
6 | Ac Output Short-Circuit Protection |
Model | IPS-PIFC3000-212 R220VAC |
IPS-PIFC3000-224 R220VAC |
IPS-PIFC3000-248 R220VAC |
||||
IPS-PIFC2500-112 R110VAC |
IPS-PIFC2500-124 R110VAC |
IPS-PIFC2500-148 R110VAC |
|||||
Output | Rated power(Wt) | 220VAC Output |
Rated power 3000W | 110VAC Output |
Rated power 2500W | ||
Peak power(Wt) | Peak power 6000W | Peak power 5000W | |||||
AC voltage (AC) | 220VC or 110VAC | ||||||
Output frequency(Hz) | 50Hz±1Hz or 60Hz±1Hz | ||||||
Output waveform | Pure sine wave at rated power input (THD<3%) | ||||||
Panel Display | LCD liquid crystal display: power % ratio, battery voltage, AC voltage, AC power, temperature display | ||||||
Input | Battery Voltage(V) | 12VDC | 24VDC | 48VDC | |||
Voltage range (V) | 10-15VDC | 20-30VDC | 40-60VDC | ||||
DC current(I) | 300A | 150A | 75A | ||||
No-load loss(W) | ≤12.9W | ||||||
Work efficiency | 88%~92% | ||||||
Battery Type | Open & sealed lead-acid batteries (customizable lithium battery parameters) | ||||||
Battery Input Protection |
Built-in fuse | 40A*12 | 40A*6 | 40A*6 | |||
Battery low voltage alert | Yes | Yes | Yes | ||||
Battery low voltage shutdown | 10V±4% | 20V±4% | 40V±4% | ||||
Battery reversal protection | By blowing the internal fuse | ||||||
Output Protection |
Over-temperature protection | Temperature greater than 85ºC turn off AC output, alarm 5 sounds/stop 5S (continuous mode) | |||||
Temperature less than 75ºC auto-recovery | |||||||
Overload protection | Load greater than 110% to 130% Continuous alarm 15 seconds to shut down AC output, (reset switch to recover) | ||||||
Load greater than 130% to 150% Continuous alarm 5 seconds to shut down AC output, (reset switch to resume) | |||||||
Load greater than 150%, 2 seconds to shut down AC output, (reset switch to recover) | |||||||
Output short circuit protection | Turn off within 2 seconds, (need to reset the switch and then resume) | ||||||
Environment | Working temperature | Ambient temperature 0ºC~+40ºC@100% load | |||||
Working humidity | 30% to 90% RH, non-condensing | ||||||
Storage temperature, humidity | -20ºC ~ +70ºC | ||||||
Vibration resistant | 10~500HZ 2G 10min/cycle, 60min for each X,Y,Z axis | ||||||
Cooling method | (Load greater than 50% open fan, less than 35% off fan) // (temperature greater than 50 ºC open fan, less than 45 ºC off fan) | ||||||
Safety EMC | Safety specifications | Compliant with CE ROSE | |||||
Pressure resistance | Bat-PG:500VAC Bat-AC:1.5KVAC AC-FG:1.5KVAC | ||||||
Insulation resistance | Bat-PG,AC -FG:100M Ohms/500VDC/25ºC/70%RH | ||||||
Product Size | 470L*264W*105H(MM) | ||||||
NW/GW | 6.5KG/8.0KG | ||||||
Remarks | 1,Efficiency test: (12.8V/25.6V/51.2V) DC input voltage, 60% power measurement. | ||||||
2, If not specifically stated: all parameters are measured at 25ºC ambient temperature | |||||||
3, Output load derating capacity reference curve1 (according to ambient temperature) | |||||||
4, Output load derating capacity reference curve 2 (battery voltage and load power relationship) |