LED Digital Adjustable Switching Variable DC Regulated Bench Power Supply for Aging Testing
I. FEATURES
1 |
Support 0-5vdc / 0-12vdc analog signal external control switching mode 200w 0-200v 0-220v Variable dc power supply |
2 |
Adjustable with Compact size, light weight |
3 |
Wide range AC Input , AC input 110V/220Vac input selected by switch |
4 |
100% full load burn-in test |
5 |
Protection: Short circuit / Over load / Over voltage |
6 |
Fixed switching frequency at 25KHz |
7 |
1 year warranty |
8 |
High efficiency, reliability quality, competitive cost |
9 |
0-5Vdc / 0-10Vdc External control output (Optional) |
10 |
Extra adjustable potentiometer (Optional) |
11 |
Output voltage adjustable, output current be fix |
II. COMMON SPECIFICATION
Adjustable range for dc voltage |
The output voltage is 100% adjustable through the potentiometer |
AC input voltage range |
AC 95-125V 60Hz | AC174-264VAC 50Hz Manual switch |
Input current |
115V/2.11A | 230V/1.06A |
AC in lash current |
Cold start current 25A/230V |
leakage current |
≤1.5mA 230V AC |
Overload protection |
Load more than 110%~120% switch to constant current mode |
Over-voltage protection |
≥15% of output voltage |
Setup rise hold time |
200ms 100ms 20ms |
Vibration |
10-50Hz, 2G 10 minutes/cycle X, Y, Z axis each 60 minutes |
Withstand voltage |
Input to shell 1500V/3mA AC | Input to output 1500V/3mA AC | Input to output 500V/3mA AC |
working temperature |
-10ºC-65ºC,20%-90%RH |
Storage temperature |
-10ºC--65ºC,20%--95%RH |
Net weight |
0.8KG |
Dimension |
200L*98W*42H(MM) |
OTHERS |
Output voltage tolerance |
1% |
Wave and noise |
150mV P-P |
Efficiency |
91% |
III. MODEL INFOMRATION
MODEL |
IPS-SP |
IPS-SP3.3-60 |
IPS-SP4.2-60 |
IPS-SP5-60 |
IPS-SP12-29 |
IPS-SP15-23.2 |
IPS-SP24-14.6 |
IPS-SP36-9.7 |
IPS-SP48-7.3 |
Output |
DC voltage |
3.3V |
4.2V |
5V |
12V |
15V |
24V |
36V |
48V |
RATED current |
60A |
60A |
60A |
29A |
23.2A |
14.6A |
9.7A |
7.3A |
Current Rated |
0-60A |
0-60A |
0-60A |
0-29A |
0-23.2A |
0-14.6A |
0-97A |
0-7.3A |
Rated power |
198W |
252W |
300W |
348W |
348W |
350.4W |
349.2W |
350.4W |
Ripple&Nosie(max)Note.2 |
150mVp-P |
150mVp-P |
150mVp-P |
150mVp-P |
150mVp-P |
150mVp-P |
200mVp-P |
200mVp-P |
Voltage adj,Range |
2.97-3.6V |
3.6-4.4V |
4.5-5.5V |
10.2-13.8V |
13.5-18V |
21.6-28.8V |
32.4V-39.6V |
43.2-52.8V |
VOLTAGE TOLERANCE Note. 3 |
±4.0% |
±4.0% |
±3.0% |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION Note .5 |
±2.5% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
SETUP RISE TIME |
1500ms . 50ms / 230VAC 1500ms . 50ms / 115VAC at full load |
HOLD UP TIME ( Typ . |
16ms / 230VAC 12ms / 115VAC at full load |
INPUT |
Voltage range |
90-132VAC /180-264VAC by switch 240VDC~370VDC(switch on 230VAC) |
Frequency range |
47~63Hz |
Efficiency (typical) |
79.5% |
81.5% |
83.5% |
85% |
86% |
88% |
88.5% |
89% |
Ac current(Typ.) |
6.8A/115VAC 3.4A/230VAC |
INRUSH CURRENT(TyP.) |
60A/115VAC 60A/230VAC |
LEAKAGE CURRENT(TyP.) |
< 2mA / 240VAC |
PROTECTIO |
OVER LOAD |
110-140% rated output power |
Protection type Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
Protection type: Shut down olp voltage, re-power on to recover |
3.8-4.45V |
4.6-5.4V |
5.75-6.75V |
13.8-16.2V |
18-21V |
28.8-33.6V |
41.4-46.8V |
55.2-64.8V |
OVER TEMPERATURE |
Hiccup mode, recovers automatically after fault condition is removed |
FUNCTION |
FAN ON/OFF CONTROL(Typ. |
RTH3≥50ºC FAN ON,≤40ºC FAN OFF |
ENVIRONMENT |
WORKING TEMP |
-30-+70C( Refer to "Derating Curve") |
WORKING HUMIDITY |
20-90% RH non-condensing |
STORAGE TEMP. HUMIDITY |
-40~+85ºC. 10~95%RH |
STORAGE TEMP. HUMIDITY |
40~+85ºC,10~95%RH |
TEMP. COEFFICIENT |
±0.03%/ºC(0-50ºC) |
VIBRATION |
0-500HZ, 5G 10min /cycle, 60min. each along X, Y, Z axes |
SAFETY |
SAFETY STANDARDS |
UL60950-1 approved |
WITHSTAND VOLTAGE |
1/P-O/P. 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC |
ISOLATION RESISTANCE |
V/P-O/P LP-FG O/- FG: 100M Chms/500VDC /25C/70%RH |
OTHERS |
MTBF |
327 9K hrs min . MIL-HDBK-217F ( 25 C ) |
DIMENSION |
215*115*30MM(L*W*H) |
PACKING |
|
NOTE |
1 . All parameters NOT specally menod are measured a 230VAC nu ed ad and 25 of ament temperature2 Rple & nose are measure a 0MHZ of bawh g a 1w w m wh a 4 l acor3 . Tolerance incudes set up tolerance , line regulation and load regulation .Line regulation is measured from low line to high line at rated load5 . Load regulation is measured fromm % to 1000% rated load6 . Length of set u time is measured at old st a T N OFF he power supply very quicky may lead to increase of the set up7 . The 150 % peak oad capab s i i for o s for 12-48 5 w n r h p mode if the peak load s deliveredfor over 1 second and will recover once ites to the rated current level ( 1 15VAC / 230VAC )8 . The ambient meare dea of 5 / 1000 is ded or oea aude greater han 2000m ( 6500ft |