2000W Switching Power Supply AC to DC 0-25V 80A 40V 50V 80V 100V 125V voltage current adjustable
Product Description
Model |
IPS-SPT20-100 |
IPS-SPT25-80 |
IPS-SPT40-50 |
IPS-SPT50-40 |
IPS-SPT100-20 |
IPS-SPT125-16 |
IPS-SPT3005 |
Item |
Technical indicators |
Output |
DC voltage |
20VDC |
25VDC |
40VDC |
50VDC |
100VDC |
125VDC |
300VDC |
Rated current |
0~100A |
0~80A |
0~50A |
0~40A |
0-20A |
0~16A |
0~5A |
Rated power |
2000W |
Ripple and noise |
<150mV |
<150mV |
<240mV |
<240mV |
<240mV |
<240mV |
<240mV |
Voltage accuracy |
±1% |
Output voltage regulation range |
0~20VDC |
0~25VDC |
0~40VDC |
0~50VDC |
0~100VDC |
0~16VDC |
0~5VDC |
Load adjustment rate |
0.3% |
Linear adjustment rate |
0.5% |
Input |
Voltage range |
180-264VAC 340-440VAC;254VDC~370VDC |
Efficiency (typical) |
>85% |
Working current |
220VAC;21A |
Impulse current |
60A 230VAC |
Start, rise, hold time |
2000ms,50ms,20ms;230VAC |
Protect |
Over temperature protection |
105% ~ 135% type; Constant current output + V0 drop undervoltage point cut-off output reset; Power on again |
Over temperature |
RTH3;The fan operates normally, ≥ N90°C, and the output is closed |
Environment |
Operating temperature, humidity |
-10°C~+50°C;20%-90RH |
Storage temperature, humidity |
-20°C~+85°C;10%~95RH |
Safety regulations |
Withstand voltage |
Input-output: 1.5kVac input housing: 1.5kVac output housing: 05kvac for 1 minute |
Leakage current |
Input-output 1.5KVAC Time< 6mA |
Leakage current |
Input-output 220VAC Time<1.5mA |
Isolation resistance |
Input-output, input-housing, output-housing,500VDC/100MΩ |
Other |
Size |
291*132*68(MM) |
NW/GW |
2.7KG/3KG |
Model table
Product Overviews