Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | IPS-APSA-28.5 Series & IPS-APSA-270 Seriesis designed to give continuous high-quality DC power. |
2 | This continuous high power model is ideal for crew training, aircraft servicing in workshops, on the ramp, or in the field, diagnostic work, pre-flight checks, charging the onboard battery, or for continuous powering of equipment during operations, without draining the onboard aircraft batteries. |
3 | The safety features include Over Voltage, Overload, and Internal Thermal, Short Circuit protection. The power modules conform to EMC standards for noise emissions and immunity |
1 | Robust metal cabinet housing |
2 | Compact size |
3 | Fixed or Mobile are available |
4 | Low ripple content ≤ 150mV (RMS) |
5 | Self diagnose and alarm |
6 | Complete protection |
Brand | IDEALPLUSING (Support OEM & ODM) | |
Model Specification | IPS-ATDA270120 or customize | |
Input | Standard | Single-phase two-wire + ground |
Voltage / Frequency | AC 220V±10% 400Hz±5% | |
Output | Power | 32400W |
Rated voltage | 270VDC or customize | |
Voltage regulation range | 0-270VDC or customize | |
Current | 120A | |
Restricted Flow Range | 0-120A | |
Machine size | Base on model | |
Net weight and gross weight | Base on model | |
Source voltage effect/load effect | ≤0.5% FS | |
DC voltage ripple | ≤0.5% FS(Vrms) | |
Output voltage display | 4-digits LCD, resolution 0.01V | |
Maximum allowable error: ≤±0.5%FS (Note: FS means full scale) | ||
Output current display | 4-digits LCD, resolution 0.1A | |
Maximum allowable error: ≤0.5%FS (10% above rated value) | ||
Insulation resistance | Input to housing and output:≥20M(DC 1000V) Output to housing:≥20M(DC 1000V) |
|
Electrical strength resistance | Input to housing and output:AC 1500V/min,Leakage current<20mA Output to housing:AC 500V/min,Leakage current<20mA |
|
Overall machine efficiency | ≥85% | |
Automatic protection function | Automatic protection in case of output overvoltage, overcurrent, module overheating and short circuit | |
Communication Interface | Communication RS485, modbus rtu protocol | |
Ambient temperature | Temperature: -10ºC-45ºC, relative humidity 10-95% (25ºC non-condensing state) | |
Dimension/Weight | Trailer type (including cable hanger): width 650 height 800 (with universal wheels) depth 600 | |
Remarks | Input with male 400hz socket GPU plug, 5m cable included Positive and negative copper cable for output |
(DC28V 0-33V)Nominal Voltage: 28.5VDC | |||||
NO | Model | INPUT (VAC) | OUTPUT VDC |
OUTPUT (AMPS) |
CAPACITY (WATTS) |
1 | IPS-ATDA28.5-50 | Single phase 220VAC 50Hz/60Hz | 0~28.5VDC | 0-50A | 1425 |
2 | IPS-ATDA28.5-100 | Single phase 220VAC 50Hz/60Hz | 0~28.5VDC | 0-100A | 2850 |
3 | IPS-ATDA28.5-200 | Single phase 220VAC 50Hz/60Hz | 0~28.5VDC | 0-200A | 5700 |
4 | IPS-ATDA28.5-400 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-400A | 14250 |
5 | IPS-ATDA28.5-500 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-500A | 14250 |
6 | IPS-ATDA28.5-600 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-600A | 17100 |
7 | IPS-ATDA28.5-800 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-800A | 22800 |
8 | IPS-ATDA28.5-1000 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-1000A | 28500 |
9 | IPS-ATDA28.5-1200 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-1200A | 34200 |
10 | IPS-ATDA28.5-1500 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-1500A | 42750 |
11 | IPS-ATDA28.5-1800 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-1800A | 51300 |
12 | IPS-ATDA28.5-2000 | 3 phases 380VAC 50Hz/60Hz | 0~28.5VDC | 0-2000A | 57000 |
(DC270V 0-330V) Nominal Voltage: 270VDC | |||||
NO | Model | INPUT (VAC) | OUTPUT VDC |
OUTPUT (AMPS) |
CAPACITY (WATTS) |
13 | IPS-ATDA270-30 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-30A | 8100 |
14 | IPS-ATDA270-50 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-50A | 13500 |
15 | IPS-ATDA270-100 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-100A | 27000 |
16 | IPS-ATDA270-150 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-150A | 40500 |
17 | IPS-ATDA270-200 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-200A | 54000 |
18 | IPS-ATDA270-300 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-300A | 81000 |
19 | IPS-ATDA270-500 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-500A | 135000 |
20 | IPS-ATDA270-800 | 3 phases 380VAC 50Hz/60Hz | 0~270VDC | 0-800A | 216000 |
Looking for a reliable and innovative Ground Power Unit to supply your aircraft?
IDEALPLUSING, no matter which type of Ground Power Unit you are looking for, we have the power to cover your needs.
We have a full range of solid-state, diesel-driven, and battery-powered Ground Power Units from 400 Hz frequency converters to 28 VDC /270 VDC Ground Power Unit or a combination.
Whether you require a power supply for hangar use, for use at aircraft parking positions, or in remote areas, we have the right solution.
We got you covered!