Customization: | Available |
---|---|
Output Power: | 300kVA |
Input Format: | 3 Phases 3 Wires+Gnd Wire |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
We specialize in customizing AC/DC/AC power supply to meet your specific requirements.
With customized any kind frequency converters, our offerings range up op to 2000KVA.
Please visit our website and submit any inquiries to explore our capabilities further. Our dedicated team endeavors to respond within one hour.
Thank you for considering our services.
Q: Why there are 50Hz and 60Hz?
A:
The frequency (50 Hz or 60 Hz) of AC power source was selected arbitrarily when systems were stand-alone (not interconnected) Therefore if you had a water mill driving a generator to power the machines in your factory it didn't really matter. This gave rise to a wide range of frequencies being used from around 15 Hz up to 90 Hz and beyond. This was OK for powering machinery. However when electric light was introduced it was clear that at any frequency below about 45 Hz you could see an incandescent light bulb flickering. Thereafter 50Hz was the general minimum. AEG in Germany drove towards 50Hz which spread throughout Europe and Westinghouse settled on 60Hz which became the norm in the US. These practices spread across the world according to areas of influence - Africa and most of Asia is 50Hz while all of the Americas, parts of Japan and the Philippines and the Pacific islands are all 60Hz. This leads to some interesting situations with US bases in Europe which have to have 60Hz generators and are generally isolated from the normal supplies. You can use a static frequency converter to change between them.
PERFORMANCE CHARACTERISTICS
1 |
Complete isolation of input and output technology, safe and reliable power supply |
2 |
SPWM sine wave pulse width modulation technology is adopted, with fast response speed and stable output |
3 |
IGBT high-frequency static inverter, small size, lightweight, low noise, and high efficiency |
4 |
The unique double-loop control mode of instantaneous value and effective value is adopted, with high control precision and good waveform quality, which can adapt to various loads |
5 |
High power IGBT module and highly integrated module drive circuit, reliable operation, strong overload capacity, low loss, and high efficiency |
6 |
Suitable for resistive, inductive, rectifier, and other loads |
7 |
It has multiple protection functions for abnormal conditions such as overheating, overcurrent, and short circuit |
8 |
It has the function of setting parameter memory, (10-groups) shortcut key operation |
9 |
The power supply voltage and frequency can be adjusted online, and the frequency can change in real-time |
APPLICATION
1 |
Home appliances |
8 |
Photovoltaic |
2 |
Motors |
9 |
Lamps |
3 |
Power tools |
10 |
Electronic transformers |
4 |
Switching power supplies |
11 |
Electronic components |
5 |
Power adapters |
12 |
Low-voltage distribution |
6 |
UPS |
13 |
Power |
7 |
Information and communication |
14 |
Other industries |
Model (IPS-FC61) |
61005 |
6101 |
6102 |
6103 |
6105 |
6106 |
6110 |
6115 |
||
Output capacity (KVA) |
0.5 |
1 |
2 |
3 |
5 |
6 |
10 |
15 |
||
Rated power output(KW) |
0.4 |
0.8 |
1.6 |
2.4 |
4 |
4.8 |
8 |
12 |
||
Circuit mode |
IGBT/SPWM |
|||||||||
AC input |
Single-phase 220V/50Hz or 60Hz |
|||||||||
AC output |
Output Phase |
Single-phase 220V |
||||||||
Voltage |
Low range |
0~150V Adjustable |
||||||||
High range |
0~300V adjustable |
|||||||||
Frequency |
40~499.9HZ can be setting by software |
|||||||||
Max current |
low-grade |
4.2A |
8.4 A |
17 A |
25 A |
42 A |
50 A |
84 A |
125 A |
|
high-grade |
2.1 A |
4.2 A |
8.4 A |
12.5 |
21 A |
25 A |
42 A |
63 A |
||
Frequency stability rate |
Frequency stability rate |
|||||||||
Load voltage stabilizing rate |
Load voltage stabilizing rate |
|||||||||
Waveform distortion degree |
Waveform distortion degree |
|||||||||
Response time |
Response time |
|||||||||
Indication resolution |
Digit frequency |
4 digits display, resolution 0.1Hz |
||||||||
Digit voltage |
4 digits virtual value display, resolution 0.1V |
|||||||||
Digit current |
4 digits virtual value display, resolution 0.01A |
|||||||||
Digit power |
4 digits virtual value display, resolution 1W |
|||||||||
Protection |
overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device |
|||||||||
Cooling |
Forced fan cooling |
|||||||||
Working temperature |
0ºC~45ºC, |
|||||||||
Environment humidity |
Relative 0~90%( non-coagulation state ) |
|||||||||
Product Dimension(cm) |
43*18*44 |
43*18*47 |
43*65*52 |
55*74*52 |
||||||
Net weight (kg) |
26 |
32 |
37 |
48 |
63 |
80 |
145 |
175 |
SPECIFICATION (IPS-FC62) SINGLE-PHASE INPUT TRI-PHASE OUTPUT
Model (IPS-FC62) |
6220 |
6230 |
6245 |
6260 |
62100 |
62120 |
621150 |
62200 |
||
Output capacity (KVA) |
20 |
30 |
45 |
60 |
100 |
120 |
150 |
200 |
||
Rated power output(KW) |
16 |
24 |
36 |
48 |
80 |
96 |
120 |
160 |
||
Circuit mode |
IGBT/SPWM |
|||||||||
AC input |
Tri-phase 220V/50Hz or 60Hz |
|||||||||
AC output |
Output Phase |
3-phases 380V |
||||||||
Voltage |
Low range |
0~150V Adjustable |
||||||||
High range |
0~300V adjustable |
|||||||||
Frequency |
40~499.9HZ can be setting by software |
|||||||||
Max current |
low-grade |
168A |
250 A |
375 A |
500 A |
834 A |
1000 A |
1250 A |
1667 A |
|
high-grade |
84 A |
125 A |
188 A |
250 A |
417 A |
500 A |
625 A |
834 A |
||
Frequency stability rate |
Frequency stability rate |
|||||||||
Load voltage stabilizing rate |
Load voltage stabilizing rate |
|||||||||
Waveform distortion degree |
Waveform distortion degree |
|||||||||
Response time |
Response time |
|||||||||
Indication resolution |
Digit frequency |
4 digits display, resolution 0.1Hz |
||||||||
Digit voltage |
4 digits virtual value display, resolution 0.1V |
|||||||||
Digit current |
4 digits virtual value display, resolution 0.01A |
|||||||||
Digit power |
4 digits virtual value display, resolution 1W |
|||||||||
Protection |
overvoltage, over current, overload, over temperature and short-circuit, as well as automatic jump protection and alarm device |
|||||||||
Cooling |
Forced fan cooling |
|||||||||
Working temperature |
0ºC~45ºC, |
|||||||||
Environment humidity |
Relative 0~90%( non-coagulation state ) |
|||||||||
Product Dimension(cm) |
58*74*52 |
70*120*110 |
80*120*150 |
100*150*160 |
||||||
Net weight (kg) |
285 |
385 |
420 |
560 |
960 |
1150 |
1450 |
1900 |
SPECIFICATION (IPS-FC63) 3-PHASES INPUT SINGLE-PHASE OUTPUT
Model IPS-FC63 |
6303 |
6306 |
6310 |
6315 |
6320 |
6330 |
6345 |
6360 |
63100 |
63120 |
63400 |
63500 |
63600 |
Rated Capacity (KVA) |
3 |
6 |
10 |
15 |
20 |
30 |
45 |
60 |
100 |
120 |
400 |
500 |
600 |
Phase Capacity (KVA) |
1 |
2 |
3.3 |
5 |
7 |
10 |
15 |
20 |
33 |
40 |
134 |
167 |
200 |
AC Input |
Single phase 220V/50Hz,60Hz |
Tri phase 380V/50Hz,60Hz |
|||||||||||
AC Output |
|||||||||||||
Phase |
Trip phase (phase difference 120°±2°) |
||||||||||||
Output Frequency |
40~499.9HZ can be setting by software | ||||||||||||
AC Voltage Output |
|||||||||||||
Low Range |
Phase voltage:0V~150V (line voltage:0V~260V) |
||||||||||||
High Range |
Phase voltage:0V~300V (line voltage:0V~520V) |
||||||||||||
Max Current output |
|||||||||||||
0~150V |
8.4A |
16.8A |
28A |
42A |
50A |
84A |
125A |
168A |
276A |
336A |
1112A |
1400A |
1667A |
0~300V |
4.2A |
8.4A |
14A |
21A |
25A |
42A |
63A |
84A |
138A |
168A |
556A |
700A |
833A |
Frequency Stability Rate |
≤±0. 1% |
||||||||||||
Load Stability Rate |
±0.5% |
||||||||||||
Waveform Distortion |
≤±2%(resistance load) |
||||||||||||
Response Time |
≤2ms |
||||||||||||
Indication Resolution |
|||||||||||||
Digit Frequency |
4 digit resolution 0.1Hz |
A,B,C |
|||||||||||
Digit Voltage |
4 digit resolution 0.1V |
||||||||||||
Digit Current |
4 digit resolution: below 4A:0.001A; above 4A:0.01A |
||||||||||||
Digit Power |
4 digit resolution 1W |
||||||||||||
Protection |
Input no fuse switch, output fuse switch, electronics circuit |
||||||||||||
Cooling |
Forced fan cooling |
||||||||||||
Environment |
|||||||||||||
Operation Temperature |
0ºC~45ºC |
||||||||||||
Relative Humility |
0~90%(non condensing ) |
||||||||||||
Working Temperature |
0ºC~45ºC, Relative 0~90%( non-coagulation state ) |
||||||||||||
Shape |
|||||||||||||
Dimensions (MM) |
190* |
280* |
620* |
950* |
700* 1340* 1280 |
1700* |
1650* |
1650* |
|||||
Weight(Kg) |
30 |
35 |
45 |
60 |
78 |
140 |
170 |
280 |
650 |
1050 |
1250 |
1350 |
1450 |
SPECIFICATION (IPS-FC68) 3-PHASES INPUT 3-PHASES OUTPUT
Model |
68005 |
6801 |
6802 |
6803 |
6805 |
6810 |
6815 |
6820 |
6830 |
6845 |
6860 |
68100 |
|
Rated Capacity |
500 |
1 |
2 |
3 |
5 |
10 |
15 |
20 |
30 |
45 |
60 |
100 |
|
Circuit Mode |
IGBT/PWM |
||||||||||||
AC Input |
Single-phase 220V/50Hz,60Hz |
Tri-phase 380V/50Hz,60Hz |
|||||||||||
AC Output |
|||||||||||||
AC Output |
Phase |
Single phase |
|||||||||||
Voltage |
Low Range |
0V~150V |
|||||||||||
Low Range |
0V~300V |
||||||||||||
Frequency |
40~499.9HZ can be setting by software | ||||||||||||
Max Current |
0V-150V |
4.2A |
8.4A |
16.8A |
25A |
42A |
84A |
126A |
168A |
250A |
375A |
500A |
834A |
0V-300V |
2.1A |
4.2A |
8.4A |
12.5A |
21A |
42A |
63A |
84A |
125A |
188A |
250A |
417A |
|
Frequency Stability Rate |
≤±0.1% |
||||||||||||
Load Stability Rate |
±0.5% |
||||||||||||
Waveform Distortion |
≤2%(linear load) |
||||||||||||
Respond Time |
Max 2ms |
||||||||||||
Indication Resolution |
|||||||||||||
Digit Frequency |
4 digit resolution 0.1Hz |
||||||||||||
Digit Voltage |
4 digit resolution 0.1V |
||||||||||||
Digit Current |
4 digit resolution below 4A:0.001A above 4A:0.01A |
||||||||||||
Digit Power |
4 digit resolution below 200W:0.1W above 200W:1W |
||||||||||||
Digit Frequency |
4 digit resolution 0.001 |
||||||||||||
Protector |
Input no fuse switch, output fuse switch, electronics circuit speed detect the over voltage, over current, over load, over temperature, short circuit and automatic jump protection and alarm. |
||||||||||||
Cooling |
Forced fan cooling |
||||||||||||
Environment |
|||||||||||||
Operate Temperature |
0ºC~45ºC |
||||||||||||
Related Humility |
0~90%(non condensing ) |
||||||||||||
Dimension H*W*D(mm) |
187*428*440 |
650*430*520 |
900*450*710 |
900*560*710 |
1200*560*800 |
1200*850*1020 |
1600*800*1200 |
COMMON SPECIFICATIONS
Phase number |
Single-phase |
Three-phase |
|
Capacity |
500VA-45KVA |
3KVA-400KVA |
|
Production method |
IGBT / PWM pulse width modulation mode |
||
Input |
Voltage (optional) |
1-Phase 2-wire + G:110V(2-5KVA) , 200V/230V/240Z±10% |
|
Output |
3-phase 4-wire + G:Y connection 190/110,200/115.208/120,220/128,230/132,240/139V±10% |
||
3-phase 4-wire + G: Y connection:380/220,400/230,415/240,400/254,460/265.480/277V±10% |
|||
3-phase 3-wire + G: delta connection:220,230,240,380,400,415,440V±10% |
|||
Frequency (optional) |
40~499.9HZ can be setting by software | ||
Voltage |
110V system:0-150V(Low Range) |
Options: 1. 0-600v; 2. Standard setting voltage: ± 10% ~ + 25%, - 10% -- 30% preset |
|
220V system:0-300V(High Range) |
|||
Load stability rate |
≤±1% |
||
Frequency |
Frequency 40.0hz to 1990.9hz (programmable) |
||
Frequency stability |
≤±0.01% |
||
Harmonic distortion |
Sine wave, ≤2% |
||
Frequency table |
4-digit, digital frequency meter, resolution 0.1hz/step |
||
Voltmeter |
4-digit, digital voltmeter, resolution 0.1V |
||
Ammeter |
4-digit, digital ammeter, resolution 0.1A |
||
Wattmeter |
4-digit, digital wattmeter, resolution 0.1W |
||
Protector |
It has overload, over high temperature, short circuit, instantaneous power-off protection and alarm device |
||
|
Temperature |
Temperature: 0-40deg. ºC |
|
Work environment |
0.90% (noncondensing state) |