High-Voltage 1200V 1A Programmable Module DC Power Supply, 1200W Aging Test Power Supply with LCD Display
Contact Supplier
Product Highlights
- Programmable Output Control: Features 30-step programmable voltage, current, and time output with list sequence loop.
- Precise Load Sensing: Built-in load-side voltage sensing terminals enable accurate reading and precise control.
- Dual Communication Protocols: Supports RS-232/485 interfaces with Modbus-RTU and SCPI protocol compatibility.
- Flexible Customization Options: Offers customized model options including specific voltage and current configurations.
- Compact 1U Design: Standard 1U half-width size suitable for workbench use and rack mounting.
- Versatile Output Modes: Supports constant voltage/current, foldback protection, pulse width, and 9999 cycles.
Product Attributes
- Customization
- Available
- Output Type
- Single
- Warranty
- 1 Year
- Model NO.
- IPS-DH10-12001
- Output Power
- 1200W
- Input Voltage
- 220V
- Connection Mode
- Parallel Switching Power Supply
- Starting Mode
- Self-excited Switching Power Supply
- Voltage Regulating Mode
- Frequency Modulation Type
- Power Supplying System
- Terminal Power Distribution Equipment
- Energy Transmission
- One-way Transmission
- Modulation System
- SMPS
- Certification
- CE
- Brand
- Idealplusing
- Model 1
- 1200VDC 0.5A 600W
- Model 2
- 1200VDC 0.8A 960W
- Model 3
- 1200VDC 1A 1200W
- Model 4
- 1200VDC 2A 2400W
- Model5
- Customized
- Transport Package
- Carton
- Specification
- 1200VDC 1A 1200W
- Trademark
- IDEALPLUSING
- Origin
- China
- Production Capacity
- 10000PCS/ Month
- Package Size
- 53.00cm * 49.00cm * 12.00cm
- Package Gross Weight
- 9.500kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of High-Voltage 1200V 1A Programmable Module DC Power Supply, 1200W Aging Test Power Supply with LCD Display
Find Similar Products
Product Description
High-voltage 1200V 1A Programmable Module DC Power Supply,1200W Aging Test Power Supply with LCD Display
Friendly Reminder
Dear Customer:
The prices shown on this page are for reference only. The final transaction price will be recalculated and quoted by our sales staff based on your actual needs, purchase quantity, and market conditions. The online prices are for your preliminary budget reference only and do not constitute a final transaction commitment.
Our company always adheres to the principle of integrity and avoids price misrepresentation. Thank you for your understanding and trust.
| 1 | Standard 1U half-width size, small volume and light weight, suitable for workbench use and rack mounting. |
| 2 | 5-digit display is clear and easy to read, with rich information displayed on the LCD screen. |
| 3 | Dual encoders for voltage and current adjustment, making operation convenient. |
| 4 | Programmable voltage, current, and time output. |
| 5 | Built-in 30-step programmable voltage, current, and time output. |
| 6 | RS-232/485 interface, supporting Modbus-RTU and SCPI communication protocols. |
| 7 | Designed with load-side voltage sensing terminals, enabling accurate reading and precise control of the load-side voltage. |
| Specifications | 30V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-30V | |||
| Model | IPS-DH10-3025 | IPS-DH10-3030 | IPS-DH10-3040 | IPS-DH10-3050 |
| Output current | 0-25A | 0-30A | 0-40A | 0-50A |
| Output power | 750W | 900W | 1200W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | |||
| Model | IPS-DH10-3060 | IPS-DH10-3080 | PS-DH10-30100 | |
| Output current | 0-60A | 80A | 100A | |
| Output power | 1800W | 2400W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 10mA | ||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 1mV | ||||
| Display method | Display method | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 50V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-50V | ||
| Model | IPS-DH10-5015 | IPS-DH10-5020 | IPS-DH10-5030 |
| Output current | 0-15A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5040 | IPS-DH10-5050 | IPS-DH10-5060 |
| Output current | 0-40A | 0-50A | 0-60A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 60V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-60V | ||
| Model | IPS-DH10-6012.5 | IPS-DH10-6025 | |
| Output current | 0-12.5A | 0-25A | |
| Output power | 750W | 1500W | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6030 | IPS-DH10-6040 | IPS-DH10-6050 |
| Output current | 0-30A | 0-40A | 0-50A |
| Output power | 1800W | 2400W | 3000W |
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 100V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-100V | |||
| Model | IPS-DH10-1007.5 | IPS-DH10-10010 | IPS-DH10-10020 | IPS-DH10-10030 |
| Output current | 0-7.5A | 0-10A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 150V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-150V | |||
| Model | IPS-DH10-1505 | IPS-DH10-15010 | IPS-DH10-15015 | IPS-DH10-15020 |
| Output current | 0-5A | 0-10A | 0-15A | 0-20A |
| Output power | 750W | 1500W | 2250W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. |
|||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. |
|||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 200V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-200V | ||
| Model | IPS-DH10-2004 | IPS-DH10-2005 | IPS-DH10-2008 |
| Output current | 0-4A | 0-5A | 0-8A |
| Output power | 800W | 1000W | 1600W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-20010 | IPS-DH10-20015 | |
| Output current | 0-10A | 0-15A | |
| Output power | 2000W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 10mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 300V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-300V | ||
| Model | IPS-DH10-3002 | IPS-DH10-3003 | IPS-DH10-3004 |
| Output current | 0-2A | 0-3A | 0-4A |
| Output power | 600W | 900W | 1200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-3005 | IPS-DH10-3008 | IPS-DH10-30010 |
| Output current | 0-5A | 0-8A | 0-10A |
| Output power | 1500W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | 1mA | ||
| Size and weight | W215*H44*L450(mm) Approximately 2.8 kg | W430*H44*L450 (mm) Approximately 3.5 kg | |
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 500V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-500V | ||
| Model | IPS-DH10-5001 | IPS-DH10-5002 | IPS-DH10-5003 |
| Output current | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5004 | IPS-DH10-5005 | IPS-DH10-5006 |
| Output current | 0-4A | 0-5A | 0-6A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 600V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-600V | ||
| Model | IPS-DH10-6001 | IPS-DH10-6002 | |
| Output current | 0-1A | 0-2A | |
| Output power | 600W | 1200W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6003 | IPS-DH10-6004 | IPS-DH10-6005 |
| Output current | 0-3A | 0-4A | 0-5A |
| Output power | 1800W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 800V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-800V | |||
| Model | IPS-DH10-8001 | IPS-DH10-8002 | IPS-DH10-8003 | IPS-DH10-8004 |
| Output current | 0-1A | 0-2A | 0-3A | 0-4A |
| Output power | 800W | 1600W | 2400W | 3200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | ||||
| Size and weight | W430*H44*L450 (mm),Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1000V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1000V | |||
| Model | IPS-DH10-10000.5 | IPS-DH10-10001 | IPS-DH10-10002 | IPS-DH10-10003 |
| Output current | 0-0.5A | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.1mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1200V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1200V | |||
| Model | IPS-DH10-12000.5 | IPS-DH10-12000.8 | IPS-DH10-12001 | IPS-DH10-12002 |
| Output current | 0-0.5A | 0-0.8A | 0-1A | 0-2A |
| Output power | 600W | 960W | 1200W | 2400W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.01mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||














| No | Model | Voltage (Volt) |
Current (Amp) |
Power (Watt) |
Dimensions (MM) |
Weight (KG) |
| 1 | IPS-DH10-3025 | 0-30V | 0-25A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 2 | IPS-DH10-3030 | 0-30V | 0-30A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 3 | IPS-DH10-3040 | 0-30V | 0-40A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 4 | IPS-DH10-3050 | 0-30V | 0-50A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 5 | IPS-DH10-3060 | 0-30V | 0-60A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 6 | IPS-DH10-3080 | 0-30V | 0-80A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 7 | IPS-DH10-30100 | 0-30V | 0-100A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 8 | IPS-DH10-5015 | 0-50V | 0-15A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 9 | IPS-DH10-5020 | 0-50V | 0-20A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 10 | IPS-DH10-5030 | 0-50V | 0-30A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 11 | IPS-DH10-5040 | 0-50V | 0-40A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 12 | IPS-DH10-5050 | 0-50V | 0-50A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 13 | IPS-DH10-5060 | 0-50V | 0-60A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 14 | IPS-DH10-6012 | 0-60V | 0-12.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 15 | IPS-DH10-6025 | 0-60V | 0-25A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 16 | IPS-DH10-6030 | 0-60V | 0-30A | 1800W | 430L*450W*44H | 4.5KG/5.5KG |
| 17 | IPS-DH10-6040 | 0-60V | 0-40A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 18 | IPS-DH10-6050 | 0-60V | 0-50A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 19 | IPS-DH10-1007 | 0-100V | 0-7.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 20 | IPS-DH10-10010 | 0-100V | 0-10A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 21 | IPS-DH10-10020 | 0-100V | 0-20A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 22 | IPS-DH10-10030 | 0-100V | 0-30A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 23 | IPS-DH10-1505 | 0-150V | 0-5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 24 | IPS-DH10-15010 | 0-150V | 0-10A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 25 | IPS-DH10-15015 | 0-150V | 0-15A | 2250W | 430L*450W*44H | 8.5KG/9.5KG |
| 26 | IPS-DH10-15020 | 0-150V | 0-20A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 27 | IPS-DH10-2004 | 0-200V | 0-4A | 800W | 215L*450W*44H | 4.5KG/5.5KG |
| 28 | IPS-DH10-2005 | 0-200V | 0-5A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 29 | IPS-DH10-2008 | 0-200V | 0-8A | 1600W | 215L*450W*44H | 4.5KG/5.5KG |
| 30 | IPS-DH10-20010 | 0-200V | 0-10A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 31 | IPS-DH10-20015 | 0-200V | 0-15A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 32 | IPS-DH10-3002 | 0-300V | 0-2.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 33 | IPS-DH10-3003 | 0-300V | 0-3A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 34 | IPS-DH10-3004 | 0-300V | 0-4A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 35 | IPS-DH10-3005 | 0-300V | 0-5A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 36 | IPS-DH10-3008 | 0-300V | 0-8A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 37 | IPS-DH10-30010 | 0-300V | 0-10A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 38 | IPS-DH10-5001 | 0-500V | 0-1A | 500W | 215L*450W*44H | 4.5KG/5.5KG |
| 39 | IPS-DH10-5002 | 0-500V | 0-2A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 40 | IPS-DH10-5003 | 0-500V | 0-3A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 41 | IPS-DH10-5004 | 0-500V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 42 | IPS-DH10-5005 | 0-500V | 0-5A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 43 | IPS-DH10-5006 | 0-500V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 44 | IPS-DH10-6001 | 0-600V | 0-1A | 600W | 215L*450W*44H | 4.5KG/5.5KG |
| 56 | IPS-DH10-6002 | 0-600V | 0-2A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 46 | IPS-DH10-6003 | 0-600V | 0-3A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 47 | IPS-DH10-6004 | 0-600V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 48 | IPS-DH10-6005 | 0-600V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 49 | IPS-DH10-8001 | 0-800V | 0-1A | 800W | 430L*450W*44H | 8.5KG/9.5KG |
| 50 | IPS-DH10-8002 | 0-800V | 0-2A | 1600W | 430L*450W*44H | 8.5KG/9.5KG |
| 51 | IPS-DH10-8003 | 0-800V | 0-3A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 52 | IPS-DH10-8004 | 0-800V | 0-4A | 3200W | 430L*450W*44H | 8.5KG/9.5KG |
| 53 | IPS-DH10-1000/05 | 0-1000V | 0-0.5A | 500W | 430L*450W*44H | 8.5KG/9.5KG |
| 54 | IPS-DH10-10001 | 0-1000V | 0-1A | 1000W | 430L*450W*44H | 8.5KG/9.5KG |
| 55 | IPS-DH10-10002 | 0-1000V | 0-2A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 56 | IPS-DH10-10003 | 0-1000V | 0-3A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 57 | IPS-DH10-1200/05 | 0-1200V | 0-0.5A | 600W | 430L*450W*44H | 8.5KG/9.5KG |
| 58 | IPS-DH10-1200/08 | 0-1200V | 0-0.8A | 960W | 430L*450W*44H | 8.5KG/9.5KG |
| 59 | IPS-DH10-12001 | 0-1200V | 0-1A | 1200W | 430L*450W*44H | 8.5KG/9.5KG |
| 60 | IPS-DH10-12002 | 0-1200V | 0-2A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |


About the Supplier
This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI211872". Items marked "" are certified.
Company Profile
What do we do?
DC-DC converter (Isolated and non-isolated), voltage from 12VDC to 1000VDC, power from 1-200kw.
AC DC power supply, voltage from 0 to 200kv, current from 0-20K AMPS.
DC AC inverter, DC voltage from 12VDC to 2000VDC, and power from 100W to 500kw.
AC AC power source, single-phase or 3-phase, 10-500Hz, power supply from 1kVA to 500kVA.
AC DC Ground Power Unit, from 300 AMPS to 50000 AMPS.
Who we are?
We have our factories (located in Shenzhen China), more than 20 cooperating factories, more than 60 workers, and 10000 different models with power supply specifications.
It is one of the suppliers of integrating, developing, manufacturing, sales, engineering design, and construction for different kinds of power supply.
We strictly implement the operation guideline of "Leading Technology, Reliable Quality, Satisfactory Service & Customers First!
We are not only selling products. We want to give you the right power supply solution, giving a better quotation solution with the right items.
Having any questions, please select the easiest method to contact us.
Remember this: Whenever you need help here in China, such as, help you contact another supplier, or sourcing some other goods you need, or...Just let me know. We will try to help.
About Our Factory & Business Background
- Address
- Building 1, No. 38 Gaopu Road, Tianhe, Guangzhou, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Huangpu
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2017-07-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the warranty period for this power supply?
- We provide a 1-year warranty for all our mechanical equipment.
- Can the output voltage and current be customized?
- Yes, we offer customized models with specific voltage and current configurations to meet your needs.
- What communication protocols are supported?
- The device supports RS-232 and RS-485 interfaces with Modbus-RTU and SCPI protocols.
- Does the power supply support programmable sequences?
- Yes, it features 30-step programmable output with configurable ON/OFF time and list sequence loops.
- What protection features are included?
- It includes Over-Voltage Protection (OVP), Over-Current Protection (OIP), and Over-Temperature Protection (OTP).
- How is the device cooled?
- The unit uses forced air cooling for efficient heat dissipation.
- What is the maximum output power available?
- The maximum output power reaches up to 3000W depending on the specific model selected.
Send your message to this supplier
People who viewed this also viewed
-
US$100.00-2,000.00 / Piece
-
US$30.48-65.32 / Piece
-
3kw High Power 100V 150VDC 0-20A 10A 3000W Adjustable 150V Variable AC to DC Power Supply with RS485US$100.00-300.00 / Piece
-
US$200.00-500.00 / Piece
-
US$30.48-65.32 / Piece
Product Groups
- Frequency converter
- Aircraft Power Unit
- Adjustable DC Power Supply
- Microwave Power Supply
- High Power DC power supply
- DC Converter-Step Down/Step Up/Boost & Down/Isolation/AC-DC
- Standard-Switching Power Supply
- Load Tester
- Programmable Power Supply
- For Electroplating electrolysis DC Power Supply
- DC DC Battery Charger
- 19inch Rack Mount Inverter(Telecom)
Find Similar Products By Category
- Supplier Homepage
- Products
- Programmable Power Supply
- 1001-2000VDC Output
- High-Voltage 1200V 1A Programmable Module DC Power Supply, 1200W Aging Test Power Supply with LCD Display
Related Categories
Hot Searches
- LED Power Supply Factories
- PC Power Supply Factories
- AC Power Supply Factories
- Industrial Power Supply Factories
- CE Dc Power Supply
- Dc Power Inverter Supply
- Dc Power Supply System
- Digital Dc Power Supply
- Industrial Dc Power Supply
- 1200V Programmable Power Supply Bulkbuy