Secured Trading Service

Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

Guangzhou Idealplusing information technology co., LTD
  • Audited Supplier
  • 6 yrs

Contact Supplier

Product Highlights

  • Programmable Output Control: Supports 30-step programmable voltage, current, and time output sequences.
  • Load-Side Voltage Detection: Built-in terminals enable accurate reading and precise control of load-side voltage.
  • Dual Communication Protocols: RS-232/485 interfaces support Modbus-RTU and SCPI communication protocols.
  • High Precision Display: 5-digit LCD display with high accuracy resolution for voltage and current readback.
  • Comprehensive Protection Systems: Features OVP, OCP, and OTP protection with freely adjustable menu settings.
  • Flexible Customization Options: Custom model available with specific voltage and current requirements.
  • Standard 1U Compact Design: Small volume and light weight suitable for workbench use and rack mounting.
  • Advanced Functionality: Includes memory mode, list sequence loop, pulse width output, and key lock.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection pictures & photos
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
  • Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
    Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

Find Similar Products

Product Description

IDEALPLUSING 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection


Friendly Reminder

Dear Customer:

The prices shown on this page are for reference only. The final transaction price will be recalculated and quoted by our sales staff based on your actual needs, purchase quantity, and market conditions. The online prices are for your preliminary budget reference only and do not constitute a final transaction commitment. 

Our company always adheres to the principle of integrity and avoids price misrepresentation. Thank you for your understanding and trust.

Product Description
1 Standard 1U half-width size, small volume and light weight, suitable for workbench use and rack mounting.
2 5-digit display is clear and easy to read, with rich information displayed on the LCD screen.
3 Dual encoders for voltage and current adjustment, making operation convenient.
4 Programmable voltage, current, and time output.
5 Built-in 30-step programmable voltage, current, and time output.
6 RS-232/485 interface, supporting Modbus-RTU and SCPI communication protocols.
7 Designed with load-side voltage sensing terminals, enabling accurate reading and precise control of the load-side voltage.
Specification
Specifications
30V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-30V
Model IPS-DH10-3025 IPS-DH10-3030 IPS-DH10-3040 IPS-DH10-3050
Output current 0-25A 0-30A 0-40A 0-50A
Output power 750W 900W 1200W 1500W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA 1mA 1mA 1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-3060 IPS-DH10-3080 PS-DH10-30100  
Output current 0-60A 80A 100A
Output power 1800W 2400W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA 1mA 10mA
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
1mV
Display method Display method
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
50V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-50V
Model IPS-DH10-5015 IPS-DH10-5020 IPS-DH10-5030
Output current 0-15A 0-20A 0-30A
Output power 750W 1000W 1500W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-5040 IPS-DH10-5050 IPS-DH10-5060
Output current 0-40A 0-50A 0-60A
Output power 2000W 2500W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
1mV
Display method Broken code screen display
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
60V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-60V
Model IPS-DH10-6012.5 IPS-DH10-6025  
Output current 0-12.5A 0-25A
Output power 750W 1500W
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-6030 IPS-DH10-6040 IPS-DH10-6050
Output current 0-30A 0-40A 0-50A
Output power 1800W 2400W 3000W
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
1mV
Display method Broken code screen display
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
100V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-100V
Model IPS-DH10-1007.5 IPS-DH10-10010 IPS-DH10-10020 IPS-DH10-10030
Output current 0-7.5A 0-10A 0-20A 0-30A
Output power 750W 1000W 2000W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA 1mA 1mA 1mA
Size and weight W215*H44*L450 Approximately 2.8kg W430*H44*L450 Approximately 3.5kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Broken code screen display
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
150V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-150V
Model IPS-DH10-1505 IPS-DH10-15010 IPS-DH10-15015 IPS-DH10-15020
Output current 0-5A 0-10A 0-15A 0-20A
Output power 750W 1500W 2250W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA 1mA 1mA 1mA
Size and weight W215*H44*L450 Approximately 2.8kg W430*H44*L450 Approximately 3.5kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Broken code screen display
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned
off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned
off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
200V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-200V
Model IPS-DH10-2004 IPS-DH10-2005 IPS-DH10-2008
Output current 0-4A 0-5A 0-8A
Output power 800W 1000W 1600W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-20010 IPS-DH10-20015  
Output current 0-10A 0-15A
Output power 2000W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
10mA
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Broken code screen display
Output overvoltage
protection
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied.
Output overcurrent
protection
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled.
Over-temperature
protection
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
300V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-300V
Model IPS-DH10-3002 IPS-DH10-3003 IPS-DH10-3004
Output current 0-2A 0-3A 0-4A
Output power 600W 900W 1200W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-3005 IPS-DH10-3008 IPS-DH10-30010
Output current 0-5A 0-8A 0-10A
Output power 1500W 2400W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA 1mA
Size and weight W215*H44*L450(mm) Approximately 2.8 kg W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
500V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-500V
Model IPS-DH10-5001 IPS-DH10-5002 IPS-DH10-5003
Output current 0-1A 0-2A 0-3A
Output power 500W 1000W 1500W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-5004 IPS-DH10-5005 IPS-DH10-5006
Output current 0-4A 0-5A 0-6A
Output power 2000W 2500W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
600V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-600V
Model IPS-DH10-6001 IPS-DH10-6002  
Output current 0-1A 0-2A
Output power 600W 1200W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W215*H44*L450 (mm) Approximately 2.8 kg
 
Model IPS-DH10-6003 IPS-DH10-6004 IPS-DH10-6005
Output current 0-3A 0-4A 0-5A
Output power 1800W 2400W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W430*H44*L450 (mm) Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
      
Specifications
800V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-800V
Model IPS-DH10-8001 IPS-DH10-8002 IPS-DH10-8003 IPS-DH10-8004
Output current 0-1A 0-2A 0-3A 0-4A
Output power 800W 1600W 2400W 3200W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.1mA
Size and weight W430*H44*L450 (mm),Approximately 3.5 kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
10mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
1000V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-1000V
Model IPS-DH10-10000.5 IPS-DH10-10001 IPS-DH10-10002 IPS-DH10-10003
Output current 0-0.5A 0-1A 0-2A 0-3A
Output power 500W 1000W 2000W 3000W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.01mA 0.1mA 0.1mA 0.1mA
Size and weight W430*H44*L450 Approximately 3.5kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
100mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
 
Specifications
1200V output series
 
AC input Single-phase 220V±10%
Frequency 50Hz/60Hz
Output voltage 0-1200V
Model IPS-DH10-12000.5 IPS-DH10-12000.8 IPS-DH10-12001 IPS-DH10-12002
Output current 0-0.5A 0-0.8A 0-1A 0-2A
Output power 600W 960W 1200W 2400W
Current readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value)
0.01mA 0.01mA 0.1mA 0.1mA
Size and weight W430*H44*L450 Approximately 3.5kg
Power stability <= 0.1%+10mV
Load stability <= 0.1%+30mV
Voltage regulation
accuracy
<= ±0.1%FS
Steady flow
accuracy
<= ±0.1%FS
Ripple (rms) ≤ 0.1%FS+10mV
Voltage setting
accuracy
±0.1%FS+10mV
Current setting
accuracy
±0.1%FS+10mA
Voltage readback
accuracy resolution
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value).
100mV
Display method Segmented display monitor
Output overvoltage
protection
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable.
The output will be shut off after protection is triggered.
Output overcurrent
protection
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable.
After protection is triggered, the output will be shut off.
Over-temperature
protection
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature).
Voltage setting Menu settings, encoder knob input
Current setting Menu settings, encoder knob input
Communication
methods
RS-485/RS-232 (supports Modbus and SCPI protocols)
Function Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999
cycles, three preset voltage and current sets (full width model), and key lock.
Output polarity The positive (+) and negative (-) outputs can be grounded arbitrarily.
Heat dissipation
method
Forced air cooling
Operating
environment
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH.
Storage
environment
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH
Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging.
Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times.
Hot selling models
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
MODEL: IPS-ATDY2075 DC Power Supply

1. AC IN: 1 phase 110/220VAC±15% 50/60HZ
2. DC OUT: 0~20VDC, 0~75A
3. Max power: 1500W
MODEL: IPS-ATDY3050 DC Power Supply

1. AC IN: 1 phase 110/220VAC±15% 50/60HZ
2. DC OUT:0~30VDC, 0~50A
3. Max power: 1500W
MODEL: IPS-ATDY5060 DC Power Supply

1. AC IN: 1 phase 110/220VAC±15% 50/60HZ
2. DC OUT:0~50VDC, 0~60A
3. Max power: 2000W
Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection
MODEL: IPS-ATDY4050 DC Power Supply

1. AC IN: 1 phase 110/220VAC±15% 50/60HZ
2. DC OUT:0~40VDC, 0~50A
3. Max power: 2000W
MODEL: ATDY12050 DC Power Supply

1. AC IN: 3-phase 380VAC±15% 50/60HZ
2. DC OUT: 0~120VDC, 0~50A
3. Max power: 6000W
MODEL: IPS-ATDY80100 DC Power Supply

1. AC IN: 3-phase 380VAC±15% 50/60HZ
2. DC OUT: 0~80VDC, 0~100A
3. Max power: 8000W
Detailed Photos

Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

Applications

Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

Model list
No Model Voltage
(Volt)
Current
(Amp)
Power
(Watt)
Dimensions
(MM)
Weight
 (KG)
1 IPS-DH10-3025 0-30V 0-25A 750W 215L*450W*44H 4.5KG/5.5KG
2 IPS-DH10-3030 0-30V 0-30A 900W 215L*450W*44H 4.5KG/5.5KG
3 IPS-DH10-3040 0-30V 0-40A 1200W 215L*450W*44H 4.5KG/5.5KG
4 IPS-DH10-3050 0-30V 0-50A 1500W 215L*450W*44H 4.5KG/5.5KG
5 IPS-DH10-3060 0-30V 0-60A 1800W 430L*450W*44H 8.5KG/9.5KG
6 IPS-DH10-3080 0-30V 0-80A 2400W 430L*450W*44H 8.5KG/9.5KG
7 IPS-DH10-30100 0-30V 0-100A 3000W 430L*450W*44H 8.5KG/9.5KG
8 IPS-DH10-5015 0-50V 0-15A 750W 215L*450W*44H 4.5KG/5.5KG
9 IPS-DH10-5020 0-50V 0-20A 1000W 215L*450W*44H 4.5KG/5.5KG
10 IPS-DH10-5030 0-50V 0-30A 1500W 215L*450W*44H 4.5KG/5.5KG
11 IPS-DH10-5040 0-50V 0-40A 2000W 430L*450W*44H 8.5KG/9.5KG
12 IPS-DH10-5050 0-50V 0-50A 2500W 430L*450W*44H 8.5KG/9.5KG
13 IPS-DH10-5060 0-50V 0-60A 3000W 430L*450W*44H 8.5KG/9.5KG
14 IPS-DH10-6012 0-60V 0-12.5A 750W 215L*450W*44H 4.5KG/5.5KG
15 IPS-DH10-6025 0-60V 0-25A 1500W 215L*450W*44H 4.5KG/5.5KG
16 IPS-DH10-6030 0-60V 0-30A 1800W 430L*450W*44H 4.5KG/5.5KG
17 IPS-DH10-6040 0-60V 0-40A 2400W 430L*450W*44H 8.5KG/9.5KG
18 IPS-DH10-6050 0-60V 0-50A 3000W 430L*450W*44H 8.5KG/9.5KG
19 IPS-DH10-1007 0-100V 0-7.5A 750W 215L*450W*44H 4.5KG/5.5KG
20 IPS-DH10-10010 0-100V 0-10A 1000W 215L*450W*44H 4.5KG/5.5KG
21 IPS-DH10-10020 0-100V 0-20A 2400W 430L*450W*44H 8.5KG/9.5KG
22 IPS-DH10-10030 0-100V 0-30A 3000W 430L*450W*44H 8.5KG/9.5KG
23 IPS-DH10-1505 0-150V 0-5A 750W 215L*450W*44H 4.5KG/5.5KG
24 IPS-DH10-15010 0-150V 0-10A 1500W 215L*450W*44H 4.5KG/5.5KG
25 IPS-DH10-15015 0-150V 0-15A 2250W 430L*450W*44H 8.5KG/9.5KG
26 IPS-DH10-15020 0-150V 0-20A 3000W 430L*450W*44H 8.5KG/9.5KG
27 IPS-DH10-2004 0-200V 0-4A 800W 215L*450W*44H 4.5KG/5.5KG
28 IPS-DH10-2005 0-200V 0-5A 1000W 215L*450W*44H 4.5KG/5.5KG
29 IPS-DH10-2008 0-200V 0-8A 1600W 215L*450W*44H 4.5KG/5.5KG
30 IPS-DH10-20010 0-200V 0-10A 2000W 430L*450W*44H 8.5KG/9.5KG
31 IPS-DH10-20015 0-200V 0-15A 3000W 430L*450W*44H 8.5KG/9.5KG
32 IPS-DH10-3002 0-300V 0-2.5A 750W 215L*450W*44H 4.5KG/5.5KG
33 IPS-DH10-3003 0-300V 0-3A 900W 215L*450W*44H 4.5KG/5.5KG
34 IPS-DH10-3004 0-300V 0-4A 1200W 215L*450W*44H 4.5KG/5.5KG
35 IPS-DH10-3005 0-300V 0-5A 1500W 215L*450W*44H 4.5KG/5.5KG
36 IPS-DH10-3008 0-300V 0-8A 2400W 430L*450W*44H 8.5KG/9.5KG
37 IPS-DH10-30010 0-300V 0-10A 3000W 430L*450W*44H 8.5KG/9.5KG
38 IPS-DH10-5001 0-500V 0-1A 500W 215L*450W*44H 4.5KG/5.5KG
39 IPS-DH10-5002 0-500V 0-2A 1000W 215L*450W*44H 4.5KG/5.5KG
40 IPS-DH10-5003 0-500V 0-3A 1500W 215L*450W*44H 4.5KG/5.5KG
41 IPS-DH10-5004 0-500V 0-4A 2400W 430L*450W*44H 8.5KG/9.5KG
42 IPS-DH10-5005 0-500V 0-5A 2500W 430L*450W*44H 8.5KG/9.5KG
43 IPS-DH10-5006 0-500V 0-6A 3000W 430L*450W*44H 8.5KG/9.5KG
44 IPS-DH10-6001 0-600V 0-1A 600W 215L*450W*44H 4.5KG/5.5KG
56 IPS-DH10-6002 0-600V 0-2A 1200W 215L*450W*44H 4.5KG/5.5KG
46 IPS-DH10-6003 0-600V 0-3A 1800W 430L*450W*44H 8.5KG/9.5KG
47 IPS-DH10-6004 0-600V 0-4A 2400W 430L*450W*44H 8.5KG/9.5KG
48 IPS-DH10-6005 0-600V 0-6A 3000W 430L*450W*44H 8.5KG/9.5KG
49 IPS-DH10-8001 0-800V 0-1A 800W 430L*450W*44H 8.5KG/9.5KG
50 IPS-DH10-8002 0-800V 0-2A 1600W 430L*450W*44H 8.5KG/9.5KG
51 IPS-DH10-8003 0-800V 0-3A 2400W 430L*450W*44H 8.5KG/9.5KG
52 IPS-DH10-8004 0-800V 0-4A 3200W 430L*450W*44H 8.5KG/9.5KG
53 IPS-DH10-1000/05 0-1000V 0-0.5A 500W 430L*450W*44H 8.5KG/9.5KG
54 IPS-DH10-10001 0-1000V 0-1A 1000W 430L*450W*44H 8.5KG/9.5KG
55 IPS-DH10-10002 0-1000V 0-2A 2000W 430L*450W*44H 8.5KG/9.5KG
56 IPS-DH10-10003 0-1000V 0-3A 3000W 430L*450W*44H 8.5KG/9.5KG
57 IPS-DH10-1200/05 0-1200V 0-0.5A 600W 430L*450W*44H 8.5KG/9.5KG
58 IPS-DH10-1200/08 0-1200V 0-0.8A 960W 430L*450W*44H 8.5KG/9.5KG
59 IPS-DH10-12001 0-1200V 0-1A 1200W 430L*450W*44H 8.5KG/9.5KG
60 IPS-DH10-12002 0-1200V 0-2A 2400W 430L*450W*44H 8.5KG/9.5KG
Company Profile

Idealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage DetectionIdealplusing 960W RS-232/485 Communication DC Power Supply 1200V 0.8A Programmable DC Power Supply with Load-Side Voltage Detection

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI211872". Items marked "verified" are certified.

Watch Video
Watch Video
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD
Guangzhou Idealplusing information technology co., LTD

About Our Factory & Business Background

Address
Building 1, No. 38 Gaopu Road, Tianhe, Guangzhou, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Huangpu

Our Production Capability & Technical Expertise

Main Products
DC Power Supply, DC/DC Converter, Pure Sine Wave Inverter, Retifier, Battery Charger, Rectifier System, Adjustable DC Power Supply, Frequency Converter, Swiching Power Supply

Our Industry Experience & Global Business Record

Export Year
2017-07-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What communication protocols are supported?
The power supply supports RS-232 and RS-485 interfaces with Modbus-RTU and SCPI protocols.
Can the output voltage and current be programmed?
Yes, it features 30-step programmable voltage, current, and time output capabilities.
What protection features are included?
It includes Over-Voltage Protection (OVP), Over-Current Protection (OCP), and Over-Temperature Protection (OTP) with adjustable settings.
Is the product customizable?
Yes, a customized model is available to meet specific voltage and current requirements.
What is the warranty period?
The product comes with a 1-year warranty.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.
What is the maximum output voltage?
The maximum output voltage reaches up to 1200V depending on the specific model selected.
How is the device cooled?
The device uses forced air cooling for heat dissipation.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs