| Customization: | Available |
|---|---|
| Output Type: | Single |
| Warranty: | 1 Year |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Hot Sale 2000W DC Adjustable Power Supply 0-50v 40a Precision Digital Programmable Power Supply for Lab Testing
Friendly Reminder
Dear Customer:
The prices shown on this page are for reference only. The final transaction price will be recalculated and quoted by our sales staff based on your actual needs, purchase quantity, and market conditions. The online prices are for your preliminary budget reference only and do not constitute a final transaction commitment.
Our company always adheres to the principle of integrity and avoids price misrepresentation. Thank you for your understanding and trust.
| 1 | Standard 1U half-width size, small volume and light weight, suitable for workbench use and rack mounting. |
| 2 | 5-digit display is clear and easy to read, with rich information displayed on the LCD screen. |
| 3 | Dual encoders for voltage and current adjustment, making operation convenient. |
| 4 | Programmable voltage, current, and time output. |
| 5 | Built-in 30-step programmable voltage, current, and time output. |
| 6 | RS-232/485 interface, supporting Modbus-RTU and SCPI communication protocols. |
| 7 | Designed with load-side voltage sensing terminals, enabling accurate reading and precise control of the load-side voltage. |
| Specifications | 30V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-30V | |||
| Model | IPS-DH10-3025 | IPS-DH10-3030 | IPS-DH10-3040 | IPS-DH10-3050 |
| Output current | 0-25A | 0-30A | 0-40A | 0-50A |
| Output power | 750W | 900W | 1200W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | |||
| Model | IPS-DH10-3060 | IPS-DH10-3080 | PS-DH10-30100 | |
| Output current | 0-60A | 80A | 100A | |
| Output power | 1800W | 2400W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 10mA | ||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 1mV | ||||
| Display method | Display method | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 50V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-50V | ||
| Model | IPS-DH10-5015 | IPS-DH10-5020 | IPS-DH10-5030 |
| Output current | 0-15A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5040 | IPS-DH10-5050 | IPS-DH10-5060 |
| Output current | 0-40A | 0-50A | 0-60A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 60V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-60V | ||
| Model | IPS-DH10-6012.5 | IPS-DH10-6025 | |
| Output current | 0-12.5A | 0-25A | |
| Output power | 750W | 1500W | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6030 | IPS-DH10-6040 | IPS-DH10-6050 |
| Output current | 0-30A | 0-40A | 0-50A |
| Output power | 1800W | 2400W | 3000W |
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 100V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-100V | |||
| Model | IPS-DH10-1007.5 | IPS-DH10-10010 | IPS-DH10-10020 | IPS-DH10-10030 |
| Output current | 0-7.5A | 0-10A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 150V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-150V | |||
| Model | IPS-DH10-1505 | IPS-DH10-15010 | IPS-DH10-15015 | IPS-DH10-15020 |
| Output current | 0-5A | 0-10A | 0-15A | 0-20A |
| Output power | 750W | 1500W | 2250W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. |
|||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. |
|||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 200V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-200V | ||
| Model | IPS-DH10-2004 | IPS-DH10-2005 | IPS-DH10-2008 |
| Output current | 0-4A | 0-5A | 0-8A |
| Output power | 800W | 1000W | 1600W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-20010 | IPS-DH10-20015 | |
| Output current | 0-10A | 0-15A | |
| Output power | 2000W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 10mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 300V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-300V | ||
| Model | IPS-DH10-3002 | IPS-DH10-3003 | IPS-DH10-3004 |
| Output current | 0-2A | 0-3A | 0-4A |
| Output power | 600W | 900W | 1200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-3005 | IPS-DH10-3008 | IPS-DH10-30010 |
| Output current | 0-5A | 0-8A | 0-10A |
| Output power | 1500W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | 1mA | ||
| Size and weight | W215*H44*L450(mm) Approximately 2.8 kg | W430*H44*L450 (mm) Approximately 3.5 kg | |
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 500V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-500V | ||
| Model | IPS-DH10-5001 | IPS-DH10-5002 | IPS-DH10-5003 |
| Output current | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5004 | IPS-DH10-5005 | IPS-DH10-5006 |
| Output current | 0-4A | 0-5A | 0-6A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 600V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-600V | ||
| Model | IPS-DH10-6001 | IPS-DH10-6002 | |
| Output current | 0-1A | 0-2A | |
| Output power | 600W | 1200W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6003 | IPS-DH10-6004 | IPS-DH10-6005 |
| Output current | 0-3A | 0-4A | 0-5A |
| Output power | 1800W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 800V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-800V | |||
| Model | IPS-DH10-8001 | IPS-DH10-8002 | IPS-DH10-8003 | IPS-DH10-8004 |
| Output current | 0-1A | 0-2A | 0-3A | 0-4A |
| Output power | 800W | 1600W | 2400W | 3200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | ||||
| Size and weight | W430*H44*L450 (mm),Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1000V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1000V | |||
| Model | IPS-DH10-10000.5 | IPS-DH10-10001 | IPS-DH10-10002 | IPS-DH10-10003 |
| Output current | 0-0.5A | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.1mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1200V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1200V | |||
| Model | IPS-DH10-12000.5 | IPS-DH10-12000.8 | IPS-DH10-12001 | IPS-DH10-12002 |
| Output current | 0-0.5A | 0-0.8A | 0-1A | 0-2A |
| Output power | 600W | 960W | 1200W | 2400W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.01mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||














| No | Model | Voltage (Volt) |
Current (Amp) |
Power (Watt) |
Dimensions (MM) |
Weight (KG) |
| 1 | IPS-DH10-3025 | 0-30V | 0-25A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 2 | IPS-DH10-3030 | 0-30V | 0-30A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 3 | IPS-DH10-3040 | 0-30V | 0-40A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 4 | IPS-DH10-3050 | 0-30V | 0-50A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 5 | IPS-DH10-3060 | 0-30V | 0-60A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 6 | IPS-DH10-3080 | 0-30V | 0-80A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 7 | IPS-DH10-30100 | 0-30V | 0-100A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 8 | IPS-DH10-5015 | 0-50V | 0-15A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 9 | IPS-DH10-5020 | 0-50V | 0-20A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 10 | IPS-DH10-5030 | 0-50V | 0-30A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 11 | IPS-DH10-5040 | 0-50V | 0-40A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 12 | IPS-DH10-5050 | 0-50V | 0-50A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 13 | IPS-DH10-5060 | 0-50V | 0-60A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 14 | IPS-DH10-6012 | 0-60V | 0-12.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 15 | IPS-DH10-6025 | 0-60V | 0-25A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 16 | IPS-DH10-6030 | 0-60V | 0-30A | 1800W | 430L*450W*44H | 4.5KG/5.5KG |
| 17 | IPS-DH10-6040 | 0-60V | 0-40A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 18 | IPS-DH10-6050 | 0-60V | 0-50A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 19 | IPS-DH10-1007 | 0-100V | 0-7.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 20 | IPS-DH10-10010 | 0-100V | 0-10A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 21 | IPS-DH10-10020 | 0-100V | 0-20A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 22 | IPS-DH10-10030 | 0-100V | 0-30A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 23 | IPS-DH10-1505 | 0-150V | 0-5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 24 | IPS-DH10-15010 | 0-150V | 0-10A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 25 | IPS-DH10-15015 | 0-150V | 0-15A | 2250W | 430L*450W*44H | 8.5KG/9.5KG |
| 26 | IPS-DH10-15020 | 0-150V | 0-20A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 27 | IPS-DH10-2004 | 0-200V | 0-4A | 800W | 215L*450W*44H | 4.5KG/5.5KG |
| 28 | IPS-DH10-2005 | 0-200V | 0-5A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 29 | IPS-DH10-2008 | 0-200V | 0-8A | 1600W | 215L*450W*44H | 4.5KG/5.5KG |
| 30 | IPS-DH10-20010 | 0-200V | 0-10A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 31 | IPS-DH10-20015 | 0-200V | 0-15A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 32 | IPS-DH10-3002 | 0-300V | 0-2.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 33 | IPS-DH10-3003 | 0-300V | 0-3A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 34 | IPS-DH10-3004 | 0-300V | 0-4A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 35 | IPS-DH10-3005 | 0-300V | 0-5A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 36 | IPS-DH10-3008 | 0-300V | 0-8A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 37 | IPS-DH10-30010 | 0-300V | 0-10A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 38 | IPS-DH10-5001 | 0-500V | 0-1A | 500W | 215L*450W*44H | 4.5KG/5.5KG |
| 39 | IPS-DH10-5002 | 0-500V | 0-2A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 40 | IPS-DH10-5003 | 0-500V | 0-3A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 41 | IPS-DH10-5004 | 0-500V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 42 | IPS-DH10-5005 | 0-500V | 0-5A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 43 | IPS-DH10-5006 | 0-500V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 44 | IPS-DH10-6001 | 0-600V | 0-1A | 600W | 215L*450W*44H | 4.5KG/5.5KG |
| 56 | IPS-DH10-6002 | 0-600V | 0-2A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 46 | IPS-DH10-6003 | 0-600V | 0-3A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 47 | IPS-DH10-6004 | 0-600V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 48 | IPS-DH10-6005 | 0-600V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 49 | IPS-DH10-8001 | 0-800V | 0-1A | 800W | 430L*450W*44H | 8.5KG/9.5KG |
| 50 | IPS-DH10-8002 | 0-800V | 0-2A | 1600W | 430L*450W*44H | 8.5KG/9.5KG |
| 51 | IPS-DH10-8003 | 0-800V | 0-3A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 52 | IPS-DH10-8004 | 0-800V | 0-4A | 3200W | 430L*450W*44H | 8.5KG/9.5KG |
| 53 | IPS-DH10-1000/05 | 0-1000V | 0-0.5A | 500W | 430L*450W*44H | 8.5KG/9.5KG |
| 54 | IPS-DH10-10001 | 0-1000V | 0-1A | 1000W | 430L*450W*44H | 8.5KG/9.5KG |
| 55 | IPS-DH10-10002 | 0-1000V | 0-2A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 56 | IPS-DH10-10003 | 0-1000V | 0-3A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 57 | IPS-DH10-1200/05 | 0-1200V | 0-0.5A | 600W | 430L*450W*44H | 8.5KG/9.5KG |
| 58 | IPS-DH10-1200/08 | 0-1200V | 0-0.8A | 960W | 430L*450W*44H | 8.5KG/9.5KG |
| 59 | IPS-DH10-12001 | 0-1200V | 0-1A | 1200W | 430L*450W*44H | 8.5KG/9.5KG |
| 60 | IPS-DH10-12002 | 0-1200V | 0-2A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |