Hot Sale 2000W AC DC Adjustable Power Supply 0-50V 40A Precision Digital Programmable Power Supply for Lab Testing
Contact Supplier
Product Highlights
- Wide Voltage Range: Available in 12 series from 0-30V to 0-1200V to meet diverse lab testing needs.
- Programmable Functions: Supports 30-step programming, list sequence loops, and configurable ON/OFF time.
- Advanced Communication: Equipped with RS-232/485 interfaces supporting Modbus-RTU and SCPI protocols.
- Compact Design: Standard 1U half-width size, lightweight, suitable for workbench or rack mounting.
- Customization Available: Model 7 is explicitly listed as 'Customized' for specific power supply requirements.
- CE Certified Quality: Product holds CE certification ensuring compliance with international safety standards.
Product Attributes
- Customization
- Available
- Output Type
- Single
- Warranty
- 1 Year
- Model NO.
- IPS-DH10-5040
- Output Power
- 2000W
- Input Voltage
- 220V
- Connection Mode
- Parallel Switching Power Supply
- Starting Mode
- Self-excited Switching Power Supply
- Voltage Regulating Mode
- Frequency Modulation Type
- Power Supplying System
- Terminal Power Distribution Equipment
- Energy Transmission
- One-way Transmission
- Modulation System
- SMPS
- Certification
- CE
- Brand
- Idealplusing
- Model 1
- 50VDC 15A 750W
- Model 2
- 50VDC 20A 1000W
- Model 3
- 50VDC 30A 1500W
- Model 4
- 50VDC 40A 2000W
- Model 5
- 50VDC 50A 2500W
- Model 6
- 50VDC 60A 3000W
- Model 7
- Customized
- Transport Package
- Carton
- Specification
- 50VDC 40A 2000W
- Trademark
- IDEALPLUSING
- Origin
- China
- Production Capacity
- 10000PCS/ Month
- Package Size
- 53.00cm * 49.00cm * 12.00cm
- Package Gross Weight
- 9.500kg
Shipping
- Shipping Cost:
- Contact the supplier about freight and estimated delivery time.
Online Trading Protection
- Payment Guarantee
-
Platform-protected payments with refund support for eligible order issues.
- Platform Logistics
- Clearer shipment tracking with platform-supported logistics.
- Inspection Service
- Optional pre-shipment inspection for quality and quantity checks.
- After-Sales & Dispute Handling
- Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Product Images of Hot Sale 2000W AC DC Adjustable Power Supply 0-50V 40A Precision Digital Programmable Power Supply for Lab Testing
Find Similar Products
Product Description
Hot Sale 2000W DC Adjustable Power Supply 0-50v 40a Precision Digital Programmable Power Supply for Lab Testing
Friendly Reminder
Dear Customer:
The prices shown on this page are for reference only. The final transaction price will be recalculated and quoted by our sales staff based on your actual needs, purchase quantity, and market conditions. The online prices are for your preliminary budget reference only and do not constitute a final transaction commitment.
Our company always adheres to the principle of integrity and avoids price misrepresentation. Thank you for your understanding and trust.
| 1 | Standard 1U half-width size, small volume and light weight, suitable for workbench use and rack mounting. |
| 2 | 5-digit display is clear and easy to read, with rich information displayed on the LCD screen. |
| 3 | Dual encoders for voltage and current adjustment, making operation convenient. |
| 4 | Programmable voltage, current, and time output. |
| 5 | Built-in 30-step programmable voltage, current, and time output. |
| 6 | RS-232/485 interface, supporting Modbus-RTU and SCPI communication protocols. |
| 7 | Designed with load-side voltage sensing terminals, enabling accurate reading and precise control of the load-side voltage. |
| Specifications | 30V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-30V | |||
| Model | IPS-DH10-3025 | IPS-DH10-3030 | IPS-DH10-3040 | IPS-DH10-3050 |
| Output current | 0-25A | 0-30A | 0-40A | 0-50A |
| Output power | 750W | 900W | 1200W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | |||
| Model | IPS-DH10-3060 | IPS-DH10-3080 | PS-DH10-30100 | |
| Output current | 0-60A | 80A | 100A | |
| Output power | 1800W | 2400W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 1mA | 1mA | 10mA | ||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 1mV | ||||
| Display method | Display method | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 50V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-50V | ||
| Model | IPS-DH10-5015 | IPS-DH10-5020 | IPS-DH10-5030 |
| Output current | 0-15A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5040 | IPS-DH10-5050 | IPS-DH10-5060 |
| Output current | 0-40A | 0-50A | 0-60A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 60V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-60V | ||
| Model | IPS-DH10-6012.5 | IPS-DH10-6025 | |
| Output current | 0-12.5A | 0-25A | |
| Output power | 750W | 1500W | |
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6030 | IPS-DH10-6040 | IPS-DH10-6050 |
| Output current | 0-30A | 0-40A | 0-50A |
| Output power | 1800W | 2400W | 3000W |
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 1mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 100V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-100V | |||
| Model | IPS-DH10-1007.5 | IPS-DH10-10010 | IPS-DH10-10020 | IPS-DH10-10030 |
| Output current | 0-7.5A | 0-10A | 0-20A | 0-30A |
| Output power | 750W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | |||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | |||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | |||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 150V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-150V | |||
| Model | IPS-DH10-1505 | IPS-DH10-15010 | IPS-DH10-15015 | IPS-DH10-15020 |
| Output current | 0-5A | 0-10A | 0-15A | 0-20A |
| Output power | 750W | 1500W | 2250W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | 1mA | 1mA | 1mA | |
| Size and weight | W215*H44*L450 Approximately 2.8kg | W430*H44*L450 Approximately 3.5kg | ||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Broken code screen display | |||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. |
|||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. |
|||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 200V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-200V | ||
| Model | IPS-DH10-2004 | IPS-DH10-2005 | IPS-DH10-2008 |
| Output current | 0-4A | 0-5A | 0-8A |
| Output power | 800W | 1000W | 1600W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-20010 | IPS-DH10-20015 | |
| Output current | 0-10A | 0-15A | |
| Output power | 2000W | 3000W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 10mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Broken code screen display | ||
| Output overvoltage protection |
The menu settings include O.V.P. protection; the protection value can be set arbitrarily, and the output will be turned off after protection is applied. | ||
| Output overcurrent protection |
The menu settings include O.I.P. protection; the protection value can be set arbitrarily, and output will be turned off after protection is enabled. | ||
| Over-temperature protection |
Built-in OTP protection, with a protection value of 85ºC ±5% (radiator temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. | ||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 300V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-300V | ||
| Model | IPS-DH10-3002 | IPS-DH10-3003 | IPS-DH10-3004 |
| Output current | 0-2A | 0-3A | 0-4A |
| Output power | 600W | 900W | 1200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-3005 | IPS-DH10-3008 | IPS-DH10-30010 |
| Output current | 0-5A | 0-8A | 0-10A |
| Output power | 1500W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | 1mA | ||
| Size and weight | W215*H44*L450(mm) Approximately 2.8 kg | W430*H44*L450 (mm) Approximately 3.5 kg | |
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 500V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-500V | ||
| Model | IPS-DH10-5001 | IPS-DH10-5002 | IPS-DH10-5003 |
| Output current | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 1500W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-5004 | IPS-DH10-5005 | IPS-DH10-5006 |
| Output current | 0-4A | 0-5A | 0-6A |
| Output power | 2000W | 2500W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 600V output series |
||
| AC input | Single-phase 220V±10% | ||
| Frequency 50Hz/60Hz | |||
| Output voltage | 0-600V | ||
| Model | IPS-DH10-6001 | IPS-DH10-6002 | |
| Output current | 0-1A | 0-2A | |
| Output power | 600W | 1200W | |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W215*H44*L450 (mm) Approximately 2.8 kg | ||
| Model | IPS-DH10-6003 | IPS-DH10-6004 | IPS-DH10-6005 |
| Output current | 0-3A | 0-4A | 0-5A |
| Output power | 1800W | 2400W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | ||
| 0.1mA | |||
| Size and weight | W430*H44*L450 (mm) Approximately 3.5 kg | ||
| Power stability | <= 0.1%+10mV | ||
| Load stability | <= 0.1%+30mV | ||
| Voltage regulation accuracy |
<= ±0.1%FS | ||
| Steady flow accuracy |
<= ±0.1%FS | ||
| Ripple (rms) | ≤ 0.1%FS+10mV | ||
| Voltage setting accuracy |
±0.1%FS+10mV | ||
| Current setting accuracy |
±0.1%FS+10mA | ||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | ||
| 10mV | |||
| Display method | Segmented display monitor | ||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | ||
| Voltage setting | Menu settings, encoder knob input | ||
| Current setting | Menu settings, encoder knob input | ||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | ||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | ||
| Heat dissipation method |
Forced air cooling | ||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | ||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | ||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | |||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | |||
| Specifications | 800V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-800V | |||
| Model | IPS-DH10-8001 | IPS-DH10-8002 | IPS-DH10-8003 | IPS-DH10-8004 |
| Output current | 0-1A | 0-2A | 0-3A | 0-4A |
| Output power | 800W | 1600W | 2400W | 3200W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.1mA | ||||
| Size and weight | W430*H44*L450 (mm),Approximately 3.5 kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 10mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1000V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1000V | |||
| Model | IPS-DH10-10000.5 | IPS-DH10-10001 | IPS-DH10-10002 | IPS-DH10-10003 |
| Output current | 0-0.5A | 0-1A | 0-2A | 0-3A |
| Output power | 500W | 1000W | 2000W | 3000W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.1mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||
| Specifications | 1200V output series |
|||
| AC input | Single-phase 220V±10% | |||
| Frequency 50Hz/60Hz | ||||
| Output voltage | 0-1200V | |||
| Model | IPS-DH10-12000.5 | IPS-DH10-12000.8 | IPS-DH10-12001 | IPS-DH10-12002 |
| Output current | 0-0.5A | 0-0.8A | 0-1A | 0-2A |
| Output power | 600W | 960W | 1200W | 2400W |
| Current readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value) | |||
| 0.01mA | 0.01mA | 0.1mA | 0.1mA | |
| Size and weight | W430*H44*L450 Approximately 3.5kg | |||
| Power stability | <= 0.1%+10mV | |||
| Load stability | <= 0.1%+30mV | |||
| Voltage regulation accuracy |
<= ±0.1%FS | |||
| Steady flow accuracy |
<= ±0.1%FS | |||
| Ripple (rms) | ≤ 0.1%FS+10mV | |||
| Voltage setting accuracy |
±0.1%FS+10mV | |||
| Current setting accuracy |
±0.1%FS+10mA | |||
| Voltage readback accuracy resolution |
5-digit meter. Accuracy: ±0.1%FS + 3 digits (10%-100% of rated value). | |||
| 100mV | ||||
| Display method | Segmented display monitor | |||
| Output overvoltage protection |
The menu allows setting OVP (Over-Voltage Protection), with the protection value being freely adjustable. The output will be shut off after protection is triggered. |
|||
| Output overcurrent protection |
The menu allows you to set O.I.P. protection, with the protection value being freely adjustable. After protection is triggered, the output will be shut off. |
|||
| Over-temperature protection |
Built-in OTP (Over-Temperature Protection), with a protection value of 85ºC ± 5% (heatsink temperature). | |||
| Voltage setting | Menu settings, encoder knob input | |||
| Current setting | Menu settings, encoder knob input | |||
| Communication methods |
RS-485/RS-232 (supports Modbus and SCPI protocols) | |||
| Function | Constant voltage/constant current, foldback current protection, memory mode, list sequence loop, configurable ON/OFF time, pulse width output, 9999 cycles, three preset voltage and current sets (full width model), and key lock. |
|||
| Output polarity | The positive (+) and negative (-) outputs can be grounded arbitrarily. | |||
| Heat dissipation method |
Forced air cooling | |||
| Operating environment |
Designed for indoor use, with a temperature range of 0ºC to 40ºC and a humidity range of 10% to 85% RH. | |||
| Storage environment |
Temperature: -20ºC~ 70ºC ; Humidity: 10% ~ 90% RH | |||
| Note: All values are typical and will be exceeded under different loads or other conditions. Accuracy is measured under load-sensing conditions; actual values may deviate from rated values due to temperature errors and component aging. | ||||
| Note: FS represents full scale. The three digits indicate that the last digit of the display will jump three times. | ||||














| No | Model | Voltage (Volt) |
Current (Amp) |
Power (Watt) |
Dimensions (MM) |
Weight (KG) |
| 1 | IPS-DH10-3025 | 0-30V | 0-25A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 2 | IPS-DH10-3030 | 0-30V | 0-30A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 3 | IPS-DH10-3040 | 0-30V | 0-40A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 4 | IPS-DH10-3050 | 0-30V | 0-50A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 5 | IPS-DH10-3060 | 0-30V | 0-60A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 6 | IPS-DH10-3080 | 0-30V | 0-80A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 7 | IPS-DH10-30100 | 0-30V | 0-100A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 8 | IPS-DH10-5015 | 0-50V | 0-15A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 9 | IPS-DH10-5020 | 0-50V | 0-20A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 10 | IPS-DH10-5030 | 0-50V | 0-30A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 11 | IPS-DH10-5040 | 0-50V | 0-40A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 12 | IPS-DH10-5050 | 0-50V | 0-50A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 13 | IPS-DH10-5060 | 0-50V | 0-60A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 14 | IPS-DH10-6012 | 0-60V | 0-12.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 15 | IPS-DH10-6025 | 0-60V | 0-25A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 16 | IPS-DH10-6030 | 0-60V | 0-30A | 1800W | 430L*450W*44H | 4.5KG/5.5KG |
| 17 | IPS-DH10-6040 | 0-60V | 0-40A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 18 | IPS-DH10-6050 | 0-60V | 0-50A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 19 | IPS-DH10-1007 | 0-100V | 0-7.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 20 | IPS-DH10-10010 | 0-100V | 0-10A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 21 | IPS-DH10-10020 | 0-100V | 0-20A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 22 | IPS-DH10-10030 | 0-100V | 0-30A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 23 | IPS-DH10-1505 | 0-150V | 0-5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 24 | IPS-DH10-15010 | 0-150V | 0-10A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 25 | IPS-DH10-15015 | 0-150V | 0-15A | 2250W | 430L*450W*44H | 8.5KG/9.5KG |
| 26 | IPS-DH10-15020 | 0-150V | 0-20A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 27 | IPS-DH10-2004 | 0-200V | 0-4A | 800W | 215L*450W*44H | 4.5KG/5.5KG |
| 28 | IPS-DH10-2005 | 0-200V | 0-5A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 29 | IPS-DH10-2008 | 0-200V | 0-8A | 1600W | 215L*450W*44H | 4.5KG/5.5KG |
| 30 | IPS-DH10-20010 | 0-200V | 0-10A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 31 | IPS-DH10-20015 | 0-200V | 0-15A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 32 | IPS-DH10-3002 | 0-300V | 0-2.5A | 750W | 215L*450W*44H | 4.5KG/5.5KG |
| 33 | IPS-DH10-3003 | 0-300V | 0-3A | 900W | 215L*450W*44H | 4.5KG/5.5KG |
| 34 | IPS-DH10-3004 | 0-300V | 0-4A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 35 | IPS-DH10-3005 | 0-300V | 0-5A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 36 | IPS-DH10-3008 | 0-300V | 0-8A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 37 | IPS-DH10-30010 | 0-300V | 0-10A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 38 | IPS-DH10-5001 | 0-500V | 0-1A | 500W | 215L*450W*44H | 4.5KG/5.5KG |
| 39 | IPS-DH10-5002 | 0-500V | 0-2A | 1000W | 215L*450W*44H | 4.5KG/5.5KG |
| 40 | IPS-DH10-5003 | 0-500V | 0-3A | 1500W | 215L*450W*44H | 4.5KG/5.5KG |
| 41 | IPS-DH10-5004 | 0-500V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 42 | IPS-DH10-5005 | 0-500V | 0-5A | 2500W | 430L*450W*44H | 8.5KG/9.5KG |
| 43 | IPS-DH10-5006 | 0-500V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 44 | IPS-DH10-6001 | 0-600V | 0-1A | 600W | 215L*450W*44H | 4.5KG/5.5KG |
| 56 | IPS-DH10-6002 | 0-600V | 0-2A | 1200W | 215L*450W*44H | 4.5KG/5.5KG |
| 46 | IPS-DH10-6003 | 0-600V | 0-3A | 1800W | 430L*450W*44H | 8.5KG/9.5KG |
| 47 | IPS-DH10-6004 | 0-600V | 0-4A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 48 | IPS-DH10-6005 | 0-600V | 0-6A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 49 | IPS-DH10-8001 | 0-800V | 0-1A | 800W | 430L*450W*44H | 8.5KG/9.5KG |
| 50 | IPS-DH10-8002 | 0-800V | 0-2A | 1600W | 430L*450W*44H | 8.5KG/9.5KG |
| 51 | IPS-DH10-8003 | 0-800V | 0-3A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |
| 52 | IPS-DH10-8004 | 0-800V | 0-4A | 3200W | 430L*450W*44H | 8.5KG/9.5KG |
| 53 | IPS-DH10-1000/05 | 0-1000V | 0-0.5A | 500W | 430L*450W*44H | 8.5KG/9.5KG |
| 54 | IPS-DH10-10001 | 0-1000V | 0-1A | 1000W | 430L*450W*44H | 8.5KG/9.5KG |
| 55 | IPS-DH10-10002 | 0-1000V | 0-2A | 2000W | 430L*450W*44H | 8.5KG/9.5KG |
| 56 | IPS-DH10-10003 | 0-1000V | 0-3A | 3000W | 430L*450W*44H | 8.5KG/9.5KG |
| 57 | IPS-DH10-1200/05 | 0-1200V | 0-0.5A | 600W | 430L*450W*44H | 8.5KG/9.5KG |
| 58 | IPS-DH10-1200/08 | 0-1200V | 0-0.8A | 960W | 430L*450W*44H | 8.5KG/9.5KG |
| 59 | IPS-DH10-12001 | 0-1200V | 0-1A | 1200W | 430L*450W*44H | 8.5KG/9.5KG |
| 60 | IPS-DH10-12002 | 0-1200V | 0-2A | 2400W | 430L*450W*44H | 8.5KG/9.5KG |


About the Supplier
This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI211872". Items marked "" are certified.
Company Profile
What do we do?
DC-DC converter (Isolated and non-isolated), voltage from 12VDC to 1000VDC, power from 1-200kw.
AC DC power supply, voltage from 0 to 200kv, current from 0-20K AMPS.
DC AC inverter, DC voltage from 12VDC to 2000VDC, and power from 100W to 500kw.
AC AC power source, single-phase or 3-phase, 10-500Hz, power supply from 1kVA to 500kVA.
AC DC Ground Power Unit, from 300 AMPS to 50000 AMPS.
Who we are?
We have our factories (located in Shenzhen China), more than 20 cooperating factories, more than 60 workers, and 10000 different models with power supply specifications.
It is one of the suppliers of integrating, developing, manufacturing, sales, engineering design, and construction for different kinds of power supply.
We strictly implement the operation guideline of "Leading Technology, Reliable Quality, Satisfactory Service & Customers First!
We are not only selling products. We want to give you the right power supply solution, giving a better quotation solution with the right items.
Having any questions, please select the easiest method to contact us.
Remember this: Whenever you need help here in China, such as, help you contact another supplier, or sourcing some other goods you need, or...Just let me know. We will try to help.
About Our Factory & Business Background
- Address
- Building 1, No. 38 Gaopu Road, Tianhe, Guangzhou, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others, FCA
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Huangpu
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2017-07-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the warranty period for this power supply?
- We provide a 1-year warranty for this product.
- Does the power supply support remote control?
- Yes, it supports RS-232/485 interfaces and is compatible with Modbus-RTU and SCPI communication protocols for remote control.
- Can the output voltage and current be programmed?
- Yes, it supports programmable voltage, current, and time output, including 30-step programming and list sequence loops.
- Is customization available for this model?
- Yes, the product attributes list 'Model 7' as 'Customized', indicating that custom specifications are available upon request.
Send your message to this supplier
People who viewed this also viewed
-
US$50.00-80.00 / Piece
-
US$200.00-500.00 / Piece
-
US$500.00-1,000.00 / Piece
Product Groups
- Static Transfer Switch
- Frequency converter
- Aircraft Power Unit
- Pure Sine Wave Inverter
- Adjustable DC Power Supply
- Microwave Power Supply
- High Power DC power supply
- DC Converter-Step Down/Step Up/Boost & Down/Isolation/AC-DC
- Standard-Switching Power Supply
- DC Load
- Programmable Power Supply
- For Electroplating electrolysis DC Power Supply
Find Similar Products By Category
- Supplier Homepage
- Products
- Programmable Power Supply
- 0-500VDC Output
- Hot Sale 2000W AC DC Adjustable Power Supply 0-50V 40A Precision Digital Programmable Power Supply for Lab Testing
Related Categories
Hot Searches
- LED Power Supply Factories
- PC Power Supply Factories
- Mobile Power Supply Factories
- AC Power Supply Factories
- CE Dc Power Supply
- Dc Power Inverter Supply
- Dc Power Supply System
- Digital Dc Power Supply
- Industrial Dc Power Supply
- Switching Power Supply Bulkbuy